*Home
*Lectures
- Model Questions
- Question Papers
- Social Media
- About
*Home
*Lectures
| references | creatinine_reference_literature_1 |
|---|---|
| creatinine_reference_literature_2 | |
| creatinine_reference_literature_3 | |
| creatinine_reference_literature_For R1_1 | |
| creatinine_reference_literature_For R1_2 | |
| creatinine_reference_literature_For R1 with SDS | |
| Note: When a new lot is opened, verify kit literature with the uploaded version. | |
| Upload newer version when required and make necessary changes in procedure and process |
| environmental and safety controls | MSDS of NAOH |
| MSDS of BRIJ35% | |
| MSDS of picric acid | |
| MSDS of SDS |
| Preparation of Creatinine reagent |
Special instructions for patients
| The examination is done on Erba XL-640. It is also done on Erbachem when Erba XL-640 is damaged and repair may take longer |
Note: Following instruction is useful only if operator is familiar with Erbachem
| Parameter | Value |
|---|---|
| Sample volume(ul) | 50 |
| Reagent volume(ul) | 500 |
| Filter | 505 nm |
| Aspitation Volume(ul) | 300 |
| Type of reaction | RATE-A |
| Decimal place | 1 |
| Linearity | 1-20mg/dl |
| Delay time | 30 sec |
| Reading time | 60 sec |
| Calibration, Result calculation, Quality control and sample examination in Erbachem |
|---|
| Prepare for calibration as below every monthly or there is relevent NC. Refer Calibrator and QC | |
|---|---|
| testing material | Replicates |
| 5% Albumin blank | 4 |
| Normal Range Calibrator | 4 |
| Abnormal range Calibrator | 4 |
| Normal range QC sera | 4 |
| Abnormal Range QC sera | 4 |