====WDI Of Cytotek==== Write number of the specimen on a clean glass slide. Place the slide in the specimen chamber holder. Place a new filter paper on the slide. Insert two tabs at the bottom of a clean specimen chamber holder. Press the top of the specimen chamber. Hold the specimen chamber holder vertically. Fill from 0.1 ml of specimen into the specimen chamber with a specimen chamber cap. Put specimen chamber holder in the centrifuge with equal instrument. Turn the ON- OFF switch on. Press the MODE keypad. Rotate the centrifuge for 10 minute with 1500 rpm. Then turn the ON-OFF switch OFF. Open the lid. Remove the rotor and place it on a flat surface. Remove the specimen chamber holders from the rotor. Remove the glass from the holder. Remove the filter paper from the surface of the slides carefully & discard in red bag Fix the slide immediately