^Equipment Documents and Records^^^ ^Requirement^Type and Location^Help^ |a.identity of the equipment|VITROS 3600-HOSP_EQ-P-|Use Equipment Name and Hospital Register page Number to create ID. It is same as in LIS cl_general.equipment.equipment\\ upload pdf of orders| |b.manufacturer’s name, model and serial number or other unique identification|VITROS 3600 immunodiagnostic system,ortho clinical diagnostic a Johnson and Johnson company Serial no-36000796 Service code-3600 {{:nchsls:c:biochemistry:document:model_no_and_serial_no.jpg?linkonly|}}|Unique ID of equipment in manufacturer's context| |c.contact information for the supplier or the manufacturer|Mr Amit-8451937779,Mr Vinay-9998291068/9924090489 Email ID-vinay.valand@menariniapac.com,For complain registration-portal link is-ocdcc.t3erp.pro and ID is -917034 and password is -civil|Address, company/local sale/engineer phone/email, number for automated complaint registration etc| |d.date of receiving and date of entering into service|7th November 2020|Same as in register| |e.location|clinical biochemistry laboratory|Lab section/room etc| |f.condition when received |new| | |g.manufacturer’s instructions|{{ :nchsls:c:biochemistry:document:v-docs_maintenence_and_troubleshoot_guide.pdf |}}-{{ :nchsls:c:biochemistry:document:v_5600user_guide.pdf |}}-{{ :nchsls:c:biochemistry:document:v56-46-36_lis_guide_-_j32799_en_2020-04-24.pdf |}}|User manual pdf| |h.Procedural document for and records that confirmed the equipment’s initial acceptability for use when equipment is incorporated in the laboratory|{{ :nchsls:c:biochemistry:document:pre_installation_report.pdf |}}-{{ :nchsls:c:biochemistry:document:pan_card_ms_office.pdf |}}-{{ :nchsls:c:biochemistry:document:bill_ms_office.pdf |}}{{ :nchsls:c:biochemistry:document:delivery_challan.pdf |}}{{ :nchsls:c:biochemistry:document:shipping_bill.pdf |}}-{{ :nchsls:c:biochemistry:document:installation_report_vitros-3602.pdf |}}{{ :nchsls:c:biochemistry:document:new_civil_surat_3600_installation_report.pdf |}}{{ :nchsls:c:biochemistry:document:vitros_3600_installation.pdf |}}|Document may be in user manual. In that case write chapter/page numbers for easy reference| |i.Record of maintenance carried out and the Procedural(schedule) document for preventive maintenance| |:::| |j.Procedural document and records that confirm the equipment’s ongoing acceptability for use;Such records include copies of reports/certificates of all calibrations and/or verifications| {{ :nchsls:c:biochemistry:document:3600_pq.pdf |}}{{ :nchsls:c:biochemistry:document:3600_pq_2_new_civil.pdf |}} {{ :nchsls:c:biochemistry:document:c-3600_pq_new_civil.pdf |}} | {{ :nchsls:c:biochemistry:document:c-3600_iq_new_civil.pdf |}}}} {{ :nchsls:c:biochemistry:document:c-3600_oq_new_civil.pdf |{{ :nchsls:c:biochemistry:document:v3600_calibration_certificate_new_civil.pdf |}}}}|:::| |k.Documented Procedure for repair and Records of damage to, or malfunction, modification, or repair of the equipment| |:::| MANUAL:-{{ :nchsls:c:biochemistry:document:6802906_3600-refgd_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j33045_3600-mntgd_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j55820_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j64210_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j65373_tb_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j66555_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j66944_en.doc |}} -{{ :nchsls:c:biochemistry:document:j66944_en.pdf |}} -{{ :nchsls:c:biochemistry:document:j66947_en.pdf |}} -[[Kit literature of all test]] -[[special instruction ]] -{{ :nchsls:c:biochemistry:document:analyte_codes_-_xt76-v56-46-36.pdf |}} -[[Troubleshooting]] -[[IQC of vitros 3600]] -[[Training points for VITROS-3600]] -{{ :nchsls:c:biochemistry:document:vitros-3600_lj_mean_and_sd.ods |}} -[[-Vitros-3600 LIS connection image]] -[[How to dilute sample manually and calculate result]] -{{ :nchsls:c:biochemistry:document:qc_vitros3600_plan.ods |}} -{{ :nchsls:c:biochemistry:document:traceability_certificate_microwell_updated_1.pdf |}} Download technical documents, including Instructions for Use, Material Safety Data Sheets, Specifications, Control Assay Sheets, Maintenance Logs, and more for Ortho Clinical Diagnostics products. https://www.orthoclinicaldiagnostics.com/en-au/home/technical-documents Microsensor check fluid level-1 and level-2 pdf {{ :nchsls:c:biochemistry:document:ilovepdf_merged.pdf |}}