^Equipment(RAPIDPOINT 500e SIEMENS_SR NO-53726_MODEL NO-11416755_HOSP-EQ-PG-80) Documents and Records^^^ ^Requirement^Type and Location^Help^ |a.identity of the equipment|RAPID POINT 500e SIEMENS_SR NO-53726_MODEL NO-11416755_HOSP-EQ-PG-80 {{ :nchsls:c:biochemistry:document:order_of_abg.pdf |}}{{ :nchsls:c:biochemistry:document:abg_analyzer_radeometer_invitromed_consumable_rc_i-order-49_abl_80.pdf |}}{{ :nchsls:c:biochemistry:document:i-order-48_abl_9.pdf |}}| Use Equipment Name and Hospital Register page Number to create ID. It is same as in LIS cl_general.equipment.equipment\\ upload pdf of orders| |b.manufacturer’s name, model and serial number or other unique identification|RAPID POINT 500 eSIEMENS_SR NO-53726_MODEL NO-11416755_HOSP-EQ-PG-80 pic-1 {{:nchsls:c:biochemistry:document:53726_serial.jpeg?400|}}|Unique ID of equipment in manufacturer's context| |c.contact information for the supplier or the manufacturer|Contact person-1st person-Mr Shirin Mistry-9004688151,2nd person-Mr Mitesh-8126830461,3rd person-Fahim Navivala contact no-9826784879 and Devendra chauhan contact no-9978936702.TALL FREE NO-18004197478.Mail id-service diagnostic@siemens.com,For consumables contact Mr Shirin Mistry.Manager contact information Darshan Doshi contact no-7228919991. |Address, company/local sale/engineer phone/email, number for automated complaint registration etc| |d.date of receiving and date of entering into service|17-02-2021|Same as in register| |e.location|Clinical Biochemistry lab|Lab section/room etc| |f.condition when received (e.g. new, used or reconditioned)|New| | |g.manufacturer’s instructions|{{ :nchsls:c:biochemistry:document:operators-guide-en.pdf |}}{{ :nchsls:c:biochemistry:document:rp500_interface-manual-en.pdf |}} |User manual pdf| |h.Procedural document for and records that confirmed the equipment’s initial acceptability for use when equipment is incorporated in the laboratory| it was received in biochemistry lab on 17-2-2020 and after receiving we opened instrument and seen all parts of the machine and attached wire seen that it is working {{ :nchsls:c:biochemistry:document:civil_iq.oq.53726.pdf |}}| It may be in user manual. In that case write chapter/page numbers for easy reference| |i.Record of maintenance carried out and the Procedural(schedule) document for preventive maintenance|:::|:::| |j.Procedural document and records that confirm the equipment’s ongoing acceptability for use;Such records include copies of reports/certificates of all calibrations and/or verifications|:::|:::| |k.Documented Procedure for repair and Records of damage to, or malfunction, modification, or repair of the equipment|:::|:::| ^Equipment(RAPIDPOINT 500 SIEMENS_SR NO-45064_MODEL NO-10697306_HOSP-EQ-PG-80) Documents and Records^^^ ^Requirement^Type and Location^Help^ |a.identity of the equipment|RAPIDPOINT 500 SIEMENS_SR NO-45064_MODEL NO-10697306_HOSP-EQ-PG-80 {{ :nchsls:c:biochemistry:document:order_of_abg.pdf |}}| Use Equipment Name and Hospital Register page Number to create ID. It is same as in LIS cl_general.equipment.equipment\\ upload pdf of orders| |b.manufacturer’s name, model and serial number or other unique identification|RAPIDPOINT 500 SIEMENS_SR NO-45064_MODEL NO-10697306_HOSP-EQ-PG-80 pic-1 {{:nchsls:c:biochemistry:document:45064.jpeg?400|}} |Unique ID of equipment in manufacturer's context| |c.contact information for the supplier or the manufacturer|Contact person-1st person-Mr Shirin Mistry-9004688151,2nd person-Mr Mitesh-8126830461,3rd person-Fahim Navivala contact no-9826784879 and Devendra chauhan contact no-9978936702 .TALL FREE NO-18004197478.Mail id-service diagnostic@siemens.com,For consumables contact Mr Shirin Mistry.Manager contact information Darshan Doshi contact no-7228919991.|Address, company/local sale/engineer phone/email, number for automated complaint registration etc| |d.date of receiving and date of entering into service|17-02-2021|Same as in register| |e.location|Clinical biochemistry lab|Lab section/room etc| |f.condition when received (e.g. new, used or reconditioned)|New| | |g.manufacturer’s instructions|{{ :nchsls:c:biochemistry:document:rp500_interface-manual-en.pdf |}}{{ :nchsls:c:biochemistry:document:operators-guide-en.pdf |}} |User manual pdf| |h.Procedural document for and records that confirmed the equipment’s initial acceptability for use when equipment is incorporated in the laboratory|it was received in biochemistry lab on 17-2-2020 and after receiving we opened instrument and seen all parts of the machine and attached wire seen that it is working {{ :nchsls:c:biochemistry:document:45064_abg_installation_report.pdf |}}{{ :nchsls:c:biochemistry:document:civil.iq.oq.45064.pdf |}}|It may be in user manual. In that case write chapter/page numbers for easy reference| |i.Record of maintenance carried out and the Procedural(schedule) document for preventive maintenance|:::|:::| |j.Procedural document and records that confirm the equipment’s ongoing acceptability for use;Such records include copies of reports/certificates of all calibrations and/or verifications|:::|:::| |k.Documented Procedure for repair and Records of damage to, or malfunction, modification, or repair of the equipment|:::|:::| - [[Training points for ABG]] - [[WDI FOR ABG]] - [[Operator's guide]] - [[How to mix sample before analysis ]] - [[Measuring range of all parameter of instrument]] - [[Troubleshooting of ABG instrument]] - ABG Sample Receiving {{ :nchsls:c:biochemistry:document:untitled_1.odt |}} - {{ :nchsls:c:biochemistry:document:vbg_refrence_rangeess2020.pdf|VBG Reference Interval reference}} - {{ :nchsls:c:biochemistry:document:how_to_prepare_heparinized_syringe-1.ods |}} - [[How to set Host connection of instrument with LIS]] Reference-{{ :nchsls:c:biochemistry:document:the_use_of_heparin_in_preparing_samples_for_blood_gas_analysis.pdf |}}