======Gently mix sample between palm 4 to 5 times====== ====== keep the sample vertical at 90 degree position with needle with cap kept as shown in below image ====== {{:nchsls:c:biochemistry:document:image-1.jpeg|}} ====== Gently push from below to remove air completely from sample and extra blood will store in cap of needle as shown in below image====== {{:nchsls:c:biochemistry:document:image-2.jpeg|}} ====== check that no air should be there in sample ====== ======Now remove needle with cap and wipe extra blood coming out from tip of syringe with cotton or gauze piece======